R30

china

Ventilator

Features:

  • Easily removable and sterilisable exhalation valve & flow sensor module.
  • Tidal volume: 20~ 2500 ml.
  • Easy to position ergonomic trolley with tow brakes.
  • Knob and hard key input.
  • Friendly user interface: TFT color screen with touch screen.
  • Sufficient modes of ventilation: VCV, PCV, SIMV-VC, SIMV-PC, SPONT/CPAP+PSV, backup.
  • Optional: (PRVC, SIMV-PRVC, Douphasic/APRV+PSV, NIV).
  • Tidal volume setting: 20 ~ 2500 ml.
  • Suitable for: adults, pediatric and infants.
  • Pneumatically driven and electronically controlled ICU ventilator.

Specifications:

  • Dimensions) H×W×D(: Ventilator: 455×400×300 mm, Trolley: 565×535×910 mm.
  • Weight: Ventilator: 12.5 kg, Trolley: 20 kg.
  • Power supply: 100-240 V, 50/60 Hz.
  • Gas supply: Air, O2, 280 kPa-600 kPa (40~87 PSI).
  • Atmospheric pressure (operation & storage): 500 hPa- 1060 hPa.
  • Relative humidity: 5-95%, non-condensing (operation), ≤ 95% non-condensing (storage).
  • Temperature: 10-40 °C (operation), -20-60 °C (storage).
  • RS232, VGA, USB, Remote alarm.
  • NI-MH battery >90 mins.
  • P-T, F-T, V-T (optional CO2-time, Pulse rate –time), Loop: P-V, F-V, P-F.
  • VCV, PCV, SIMV-VC, SIMV-PC, CPAP/PSV, (Optional: APRV, PRVC, VS, NIV) back up.
  • Data communication port.
  • Display: Respiratory mode.
  • Graphical display, 10.4” TFT display, with touch screen.
  • Standards: IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 6060, IEC 60601-2-12.

Good integration:

  • Optional: etCO2 monitoring module.
  • Manual inspiration.
  • 100 % suction.
  • Expiratory hold with PEEPi measurement.
  • Inspiratory hold with static compliance measurement.
  • Lung mechanics parameters and loops.
  • Built-in battery (≥90mins).
  • Built-in synchronized nebulizer.
  • Built-in O2 & air mixture device.
  • Built-in active expiratory PEEP valve.

Suction: The FiO2 can be set in R30 suction procedure. Three phases suction support will be performed to verify patient’s SPO2. Smart detection will switching automatically for patient disconnection and reconnection.

PRVC: PRVC is a control mode which deliver set rate volume (VT) to patient. The flow will be delivered as pressure control mode, inspiratory pressure regulated to achieve the set volume (TV), PRVC will verify patient’s minute volume, and protect patient in high peak pressure.

 

  • System log can record 100 settings/alarm.
  • 3 waveforms and loops on one interface, quick changeover.
  • Direct setting of ventilation parameters in main interface.
  • Patient settings automatic stored and can be restored quickly.
  • Quick self-test no need frequent interaction from operator.
  • Color coded display for numerical, graphic, alarm and system message.

Advanced features: inspiration hold after the breath, the special function display area will show the value of system static compliance (Cst), measurement. Expiration hold, after using this key special features will display the measured intrinsic PEEP on the device display interface area.

Multiple alarm system: well organized display layout visualizes all relevant respiratory parameters, the patient’s vital signs can be assessed quickly and comprehensively.